Current crowding at the bends
Critical-current factor R against spacing
R = Ic(with bend) / Ic(straight wire), for a 180-degree bend at the given width and ξ. The vertical line is the given spacing.
All three lines use the same model (the paper's vortex-energy criterion, written for all inner-edge shapes). Optimised bend: the best shape that the optimiser finds; for g ≥ 2W it is the paper's optimal bend, R = 1. Dotted line: a proved upper bound of R for all inner-edge shapes at constant pitch. The bound is not tight: for small ξ/W the optimised bend is within 0.01 of it, for ξ/W near 0.1 the distance is about 0.06. Tests with longer tapers and finer grids did not increase the optimised value.
Detector estimates at the operating conditions
Simple closed formulas (sources in operating.py). "-" = an input is not